JIS A 6111:2016 Roof Underlayment Supply for Japanese Distributors
JIS A 6111:2016 Roof Underlayment Supply for Japanese Distributors

A roofing-accessories distributor based in Nagoya sells to contractors across Aichi and Gifu prefectures. In August 2025 they ran a comparison for a permeable roofing underlay, to be installed under standing-seam metal sheet on pitched roofs.
Two of the four samples they had collected carried datasheets citing JIS A 6111:2004. That edition no longer matches the standard in force, so the distributor asked us to quote against the current edition and to supply documentation their contractors could hand to a building inspector without a follow-up round of questions.
What the project required
Product standard: JIS A 6111:2016, permeable membrane sheets used as roofing underlay.
Water tightness and vapour resistance matched to the cold-zone roof assembly, so the membrane does not become the condensation risk it is meant to prevent.
Roll width matched to the contractor's 1,000 mm laying pattern, to hold membrane waste down.
UV stability documented for the period the membrane stays exposed before the final roof covering goes on.
Installation sheet in Japanese, because the crew works from printed instructions on site.
What we supplied
A three-layer polypropylene underlay: spunbond PP outer layer, microporous breathable film core, spunbond PP inner layer, at 110 g/m² for covered roof build-ups and 150 g/m² where the membrane stays exposed for longer periods.
The documentation set shipped with the material: test reports keyed clause by clause to JIS A 6111:2016, a lot-level certificate of analysis, a two-side A4 datasheet in Japanese, an installation sheet covering overlap, taping and counter-batten detail, and the safety data sheet for the flame-retardant grade where applicable.
Outcome
The distributor placed a first order of 42,000 m² and reused our documentation set inside their own customer reply, which shortened their internal approval step. Repeat orders have since been placed on the same construction at 1,500 mm width, in March and July 2026. No field complaint on water tightness or on the exposure period has been raised in the eleven months since the first delivery.
What this means if you buy underlay for Japan
Ask for the standard number with its year. A datasheet citing JIS A 6111:2004 is a version error, not a typo.
Fix the exposure period before choosing gram weight. The same membrane can be right for a covered roof and wrong for one that stays open for months.
Ask for the installation sheet in the language the crew actually reads. It is part of the deliverable, not an extra.
Related Projects