Overview

Building membranes serve different functions depending on their location in the building envelope. This guide helps you select the right membrane for your application.

Application Categories

Roofing Underlay

Installed beneath roof tiles or metal roofing as secondary waterproofing:

  • Key requirement: Water tightness (W1 or W2)
  • Breathability: Sd value ≤0.25m
  • UV resistance: Required if exposed during construction
  • Fire rating: B-s1,d0 minimum, A2-s1,d0 for high-rise

Wall Breather Membranes

Installed on the cold side of insulation in wall systems:

  • Key requirement: Water resistance with high vapour permeability
  • UV resistance: Critical for open-jointed cladding (5000h minimum)
  • Fire rating: A2-s1,d0 for buildings over 18m

Ground Gas Barriers

Installed below slab to protect against ground gases:

  • Key requirement: Gas resistance (methane, radon, VOCs)
  • Water resistance: Must also provide waterproofing
  • Durability: 30+ year design life
  • Joint integrity: Welded or taped seams

Vapour Control Layers

Installed on the warm side of insulation to control condensation:

  • Key requirement: Low water vapour permeability
  • Fire rating: A2-s1,d0 for high-rise applications
  • Durability: Must last building lifetime

Selection Matrix

ApplicationPrimary FunctionKey PropertyRecommended Product
Pitched roofSecondary waterproofingWater tightness W1Roofing Underlay
Open-jointed façadeWeather protectionUV resistance 5000hUV-Resistant Breather Membrane
High-rise wallFire safety + weatherA2-s1,d0 fire ratingHigh-performance fire-rated breather membrane
Brownfield siteGas protectionGas resistanceGround Gas Barrier Membrane